Calibration T Connector

Calibration T Connector

Welch Allyn

Blood Pressure Accessories
  • OEM accessory manufactured by Welch Allyn under ISO 13485 Compliant medical device quality systems (via Hillrom/Baxter).
  • Designed for use with regulated Welch Allyn vital signs and blood pressure devices as part of their recommended calibration procedures.
  • Non Sterile accessory that does not itself constitute a standalone medical device for patient treatment but supports compliance with device quality Control requirements.
Calibration connector for vital signs/blood pressure devices

Description

The Welch Allyn Calibration T-Connector (part number 5200-08) is an OEM accessory designed to facilitate calibration and functional testing of Welch Allyn blood pressure and vital signs systems, particularly the Spot Vital Signs and Spot Vital Signs LXi monitors. The connector interfaces between a blood pressure device, cuff/tubing and an external reference calibrator, forming a T-shaped connection that enables pressure to be applied and measured simultaneously. This allows biomedical and clinical engineering staff to verify that the device’s non-invasive blood pressure (NIBP) readings correspond accurately to a certified reference, supporting ongoing accuracy, safety and compliance with quality-control standards.

Bnefits

  • Enables convenient connection between Welch Allyn Spot Vital Signs / Spot Vital Signs LXi monitors (and compatible systems), the blood pressure cuff, and an external pressure reference for NIBP calibration and testing.
  • Supports routine quality control by allowing verification and adjustment of blood pressure readings against a calibrated standard.
  • OEM Welch Allyn accessory (5200-08), ensuring correct fit with the manufacturer’s tubing and ports and maintaining system integrity.
  • Simple, passive mechanical connector with no moving or electronic parts, minimising maintenance requirements and complexity.
  • Compact and lightweight, easy to store in biomedical engineering toolkits or device accessory drawers.
  • Helps facilities comply with internal policies and external accreditation requirements for regular device calibration checks.

Indications

  • Use as a calibration and test connector for Welch Allyn Spot Vital Signs and Spot Vital Signs LXi monitors, and other compatible Welch Allyn devices as specified by the manufacturer.
  • Routine preventive maintenance and scheduled performance verification of non-invasive blood pressure modules.
  • Post-repair or post-impact accuracy checks to confirm proper function of Welch Allyn NIBP equipment.
  • Use by biomedical engineering, clinical engineering or technical staff as part of a broader calibration procedure involving a reference manometer or NIBP simulator.

Composition

  • T-shaped connector body designed to interface with Welch Allyn blood pressure tubing and ports.
  • Multiple barbed or ported ends (depending on configuration) to connect device tubing, cuff tubing and an external calibration or reference device.
  • Manufactured from durable, medical-grade plastic suitable for repeated handling and typical service conditions (exact polymer not specified in public listings).
  • Non-sterile, non-patient-contact component intended solely for equipment calibration.

Formulation

  • Mechanical plastic connector only; contains no medicinal, electronic or active components.

Packaging

  • Supplied individually (pack size: 1 each) as noted in distributor listings.
  • Typically packed in a small labelled pouch or box identifying the product as a Welch Allyn Calibration T-Connector, part number 5200-08.
  • Shipped within protective outer packaging to prevent damage during transit.

Usage

  • Use only by appropriately trained technical or clinical personnel familiar with calibration of Welch Allyn NIBP and vital signs devices.
  • Before use, visually inspect the T-connector for cracks, deformation or contamination; do not use a damaged connector.
  • Follow the manufacturer’s device-specific calibration procedure, which typically includes: connecting one leg of the T-connector to the device’s blood pressure port or tubing, a second leg to the blood pressure cuff or test bladder, and the third leg to an external reference manometer or NIBP simulator.
  • Ensure all tubing connections are fully seated and secure to prevent leaks during pressurisation.
  • Apply pressure using the appropriate bulb, pump or simulator; observe and compare the readings on the Welch Allyn device with the reference instrument in accordance with the calibration protocol.
  • If readings fall outside acceptable limits, follow the device service manual for recalibration, adjustment or service escalation.
  • After testing, carefully depressurise the system, disconnect tubing, and store the T-connector in a clean, dry location designated for calibration accessories.
  • Clean the external surfaces as needed with a soft cloth lightly moistened with a manufacturer-approved cleaning agent; do not autoclave or expose to high temperatures unless explicitly permitted in Welch Allyn documentation.

Contraindications

  • Not for direct patient use or contact; the connector is intended solely for equipment calibration and should not be left in-line during normal patient monitoring.
  • Do not use with non-compatible devices or tubing systems that are not specified by Welch Allyn, as improper fit may lead to leaks or inaccurate calibration.
  • Do not use a damaged, cracked or visibly worn connector, as this may compromise calibration accuracy or cause leaks.

Adverse Effects

  • No direct patient adverse effects are expected because the device is used only for equipment calibration and not in direct contact with patients.
  • Potential indirect risk exists if calibration is performed incorrectly or with a damaged connector, leading to inaccurate blood pressure readings during subsequent patient monitoring.

Storage Conditions

  • Store at room temperature in a clean, dry environment.
  • Protect from excessive heat, direct sunlight and moisture, which could degrade plastic materials over time.
  • Avoid crushing, bending or placing heavy objects on top of the connector to prevent deformation.
  • Keep with other calibration accessories in a designated storage area accessible to technical staff.

Duration

Onset

Browse more Blood Pressure Accessories

ELI 150c Resting Electrocardiograph

ELI 150c Resting Electrocardiograph

Medisave

ELI 150c Resting Electrocardiograph

Medical and Aesthetic Equipment
  • £4,822.79
  • £4,078.79
  • 5 more

MicroTymp3 Tips - 4 Extra Small (7 mm) for Welch Allyn otoscopes

MicroTymp3 Tips - 4 Extra Small (7 mm) for Welch Allyn otoscopes

Medisave

MicroTymp3 Tips - 4 Extra Small (7 mm) for Welch Allyn otoscopes

Medical and Aesthetic Equipment
  • £25.99
  • £28.99
  • 7 more

ELI150c Resting Electrocardiograph with Wireless Patient Cable Module (WAM), Ethernet LAN, XML & PDF, UK Plug

ELI150c Resting Electrocardiograph with Wireless Patient Cable Module (WAM), Ethernet LAN, XML & PDF, UK Plug

Medisave

ELI150c Resting Electrocardiograph with Wireless Patient Cable Module (WAM), Ethernet LAN, XML & PDF, UK Plug

Medical and Aesthetic Equipment
  • £3,091.19
  • £2,762.39
  • 3 more

Welch Allyn Connex Spot Monitor with SureBP Non-Invasive Blood Pressure, Covidien SpO2 and Braun ThermoScan PRO 6000 Thermometry – Plug 4

Welch Allyn Connex Spot Monitor with SureBP Non-Invasive Blood Pressure, Covidien SpO2 and Braun ThermoScan PRO 6000 Thermometry \u2013 Plug 4

Medisave

Welch Allyn Connex Spot Monitor with SureBP Non-Invasive Blood Pressure, Covidien SpO2 and Braun ThermoScan PRO 6000 Thermometry – Plug 4

Medical and Aesthetic Equipment
  • £736.79
  • £571.19
  • 3 more

Welch Allyn Comfort Sealing Eartips (Large, one pair)

Welch Allyn Comfort Sealing Eartips (Large, one pair)

Medisave

Welch Allyn Comfort Sealing Eartips (Large, one pair)

Medical and Aesthetic Equipment
  • £5.49
  • £35.99
  • 2 more

Miller 00 Fiber Optic Laryngoscope Blade

Miller 00 Fiber Optic Laryngoscope Blade

Medisave

Miller 00 Fiber Optic Laryngoscope Blade

Medical and Aesthetic Equipment
  • £206.39
  • £206.39
  • 2 more

ProBP™ 2000 Digital Blood Pressure Device with Power Supply - CLEARANCE

ProBP\u2122 2000 Digital Blood Pressure Device with Power Supply - CLEARANCE

Medisave

ProBP™ 2000 Digital Blood Pressure Device with Power Supply - CLEARANCE

Medical and Aesthetic Equipment
  • £87.59
  • £257.99
  • 2 more

GS777 Integrated Wall System, PanOptic, MacroView for CSM UK

GS777 Integrated Wall System, PanOptic, MacroView for CSM UK

Medisave

GS777 Integrated Wall System, PanOptic, MacroView for CSM UK

Medical and Aesthetic Equipment
  • £2,279.99
  • £2,243.99
  • 0 more

Welch Allyn SureBP Double-Tube Blood Pressure Hose, 10 ft (3.0 m)

Welch Allyn SureBP Double-Tube Blood Pressure Hose, 10 ft (3.0 m)

Medisave

Welch Allyn SureBP Double-Tube Blood Pressure Hose, 10 ft (3.0 m)

Medical and Aesthetic Equipment
  • £80.39
  • £64.79
  • 1 more

ELI 230 Resting Electrocardiograph with Wireless Patient Cable Module (WAM), UK Plug

ELI 230 Resting Electrocardiograph with Wireless Patient Cable Module (WAM), UK Plug

Medisave

ELI 230 Resting Electrocardiograph with Wireless Patient Cable Module (WAM), UK Plug

Medical and Aesthetic Equipment
  • £1,689.59
  • £1,919.99
  • 0 more

ProBP 2400 Blood Pressure Cuff, Large Adult Long (32 - 52cm)

ProBP 2400 Blood Pressure Cuff, Large Adult Long (32 - 52cm)

Medisave

ProBP 2400 Blood Pressure Cuff, Large Adult Long (32 - 52cm)

Medical and Aesthetic Equipment
  • £46.79
  • £56.39
  • 1 more

ECG Thermal Z-Fold to Use With ELI150/150C - 1 Pack of 200 Sheets

ECG Thermal Z-Fold to Use With ELI150/150C - 1 Pack of 200 Sheets

Medisave

ECG Thermal Z-Fold to Use With ELI150/150C - 1 Pack of 200 Sheets

Medical and Aesthetic Equipment
  • £32.39
  • £14.39
  • 1 more